ABSTRACT
Objective: Curcumin and piperine exibit poor aqueous solubility and dissolution. Solid dispersion technology is a promising way to improve dissolution of lipophilic compounds. Therefore, to investigate the dissolution behavior, an accurate determination of curcumin and piperine concentrations in a sample containing 0.5 wt-% SLS in sodium phosphate buffer as the dissolution medium was required. The goal of research was to investigate whether UV-Vis spectroscopy can be used to accurately determine curcumin and piperine concentrations in aqueous solutions.Method: Stock solutions (1 mg/mL) of curcumin and piperine were prepared in methanol. A series of solutions for calibration were prepared by mixing the stock solutions in various ratios after which they were diluted with dissolution medium (0.5%-wt sodium lauryl sulfate in 20 mM phosphate buffer; pH 6.0). Solutions of curcumin (2μg/mL) and piperine (1 μg/mL were subjected to overlay scan in a UV-VIS spectrophotometer in each λmax of 430 and 335.5 nm for curcumin and piperine, respectively. The method was validated according ICH requirements, such as specificity, linearity, accuracy, precision, limit of detection and limit of quantification.Results: At a concentration range of 0.1 to 5μg/mL, calibration curves of curcumin and piperine showed linearity with R2 = 0.9980 and 0.9982, respectively. Precision and accuracy was confirmed by AOAC. Furthermore, LOD of both compounds was 0.23 μg/mL and LOQ of curcumin and piperine was 0.72 and 0.69 μg/mL, respectively.Conclusion: UV-Vis spectroscopy can be used to accurately determine curcumin and piperine concentrations in dissolution samples obtained during screening the dissolution behavior of solid dispersions containing these compounds.
KEYWORDS
REFERENCES
As publishedShowing references and in-text citations exactly as published.
Cite this article
SELECT FORMAT
Murti, Y. B., Hartini, Y. S., Hinrichs, W. L. J., Frijlink, H. W., & Setyaningsih, D. (2019). UV-Vis Spectroscopy to Enable Determination of the Dissolution Behavior of Solid Dispersions Containing Curcumin and Piperine. Journal of Young Pharmacists, 11(1), 26-30. https://doi.org/10.5530/jyp.2019.11.6
Copyright and licence
© 2019 Author(s)
This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. CC BY-NC-SA 4.0