Development and Validation of an RP-HPLC Method for Determination of Solasodine, a Steroidal Alkaloid
1,2, 1,2★, 1,2, 3, 4, 5★ Corresponding author
- 1Department of Pharmacognosy, Faculty of Pharmacy Kerman University of Medical Sciences, Kerman, IRAN.
- 2Department of Pharmacognosy, Faculty of Pharmacy, Kerman University of Medical Sciences, Kerman, IRAN.
- 3Department of Pharmaceutics, Faculty of Pharmacy, Kerman University of Medical Sciences, Kerman, IRAN.
- 4Department of Medicinal Chemistry, Faculty of Pharmacy, Kerman University of Medical Sciences, Kerman, IRAN.
- 5Central laboratory, Deputy of research, Kerman university of Medical Sciences, Kerman, IRAN.
CORRESPONDENCE
Mitra Mehrabani
Department of Pharmacognosy, Faculty of Pharmacy Kerman University of Medical Sciences, Kerman, IRAN.
Received: 11-05-2018; Revised: 19-07-2018; Accepted: 03-10-2018.
Volume 11, Issue 1 · pp. 21-25 · 2019 · DOI: 10.5530/jyp.2019.11.5
ABSTRACT
Objective: The aim of the present study was to optimize an RP-HPLC method for determination of solasodine, a steroidal alkaloid with various pharmacologic properties, in herbal medicinal preparations.Methods: Various chromatographic parameters including the composition of mobile phase and its organic and pH modifiers, mode of elution and column temperature were investigated using analytical C18 columns as stationary phase. Acetonitrile and methanol were examined in combination with deionized water and different aqueous buffers as mobile phases.Results: A mixture of methanol: KH2 PO4 buffer (pH 2.5) at the ratio of 75:25 %v/v in an isocratic elution mode produced more symmetric, sharper peaks with better retention times and capacity factor than that of acetonitrile: KH2 PO4 buffer. The optimum column temperature was found at 25°C. The standard calibration curve showed a very good linearity (R2 =0.9966) in the range of 1-25 μg/ml with acceptable inter-day and intra-day precisions and accuracy. In addition, the LOD and the LOQ of the method were determined at 0.2 and 0.7 μg/mL, respectively.Conclusion: This developed and validated method is simple and quite rapid and can be used for routine determination of solasodine in samples such as traditional medicinal preparations.
KEYWORDS
REFERENCES
As publishedShowing references and in-text citations exactly as published.
Cite this article
SELECT FORMAT
Khandani, S. K., Mehrabani, M., Sharififar, F., Pardakhty, A., Pournamdari, M., & Pakravanan, M. (2019). Development and Validation of an RP-HPLC Method for Determination of Solasodine, a Steroidal Alkaloid. Journal of Young Pharmacists, 11(1), 21-25. https://doi.org/10.5530/jyp.2019.11.5
Copyright and licence
© 2019 Author(s)
This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. CC BY-NC-SA 4.0
