Home Uncategorized Estimation of plasma levels of warfarin and 7-hydroxy warfarin by high performance liquid chromatography in patients receiving warfarin therapy

Estimation of plasma levels of warfarin and 7-hydroxy warfarin by high performance liquid chromatography in patients receiving warfarin therapy

by admin

Published on:
Journal of Young Pharmacists, 2013; 5(1):13-17
Original article | doi:10.1016/j.jyp.2013.02.001
Authors:

Dhakchinamoorthi Krishna Kumar a,*, Deepak Gopal Shewade a, Subramani Parasuraman a, Sundaram Rajan a, Jayaraman Balachander b, B.V. Sai Chandran c, Chandrasekaran Adithan a

a Department of Pharmacology, Jawaharlal Institute of Postgraduate Medical Education & Research (JIPMER), Pondicherry 605 006, India.

b Department of Cardiology, Jawaharlal Institute of Postgraduate Medical Education & Research (JIPMER), Pondicherry 605 006, India.

c Department of Cardiothoracic and Vascular Surgery, Jawaharlal Institute of Postgraduate Medical Education & Research (JIPMER), Pondicherry 605 006, India.

Abstract:

Warfarin is one of the most commonly prescribed oral anticoagulant for prevention of thromboembolic events. The effect of this drug is measured by monitoring prothrombin time expressed as International Normalized Ratio (INR). In some cases, however, the measurement of plasma concentration of warfarin was emphasized. In the present study, reversed phase high performance liquid chromatography (HPLC) was used to estimate the plasma drug levels. A total of 185 patients were enrolled in this study. Five milliliter of venous blood was collected using sodium EDTA tubes for pharmacokinetic analysis. Solid phase extraction was used to recover the warfarin and it’s metabolite from plasma using isopropanol and potassium phosphate buffer (40:60) mobile phase. Warfarin, 7-hydroxy warfarin and carbamazepine (internal standard) were separated on a C18 column and had the retention time 3.6 min, 2.9 min and 5.9 min, respectively. The assay was linear in warfarin concentration ranges of 0.1-5 µg/ml. The extraction recovery was found to be x85%. The mean plasma concentrations of warfarin and 7-hydroxy warfarin were found to be 3.47 ± 1.87 (SD) µg/ml, 1.25 ± 0.81 (SD) µg/ml, respectively. Through the present study the plasma concentrations of warfarin, 7-hydroxy warfarin and their metabolic ratio was determined. The assay was sensitive to follow warfarin pharmacokinetics in a patient with warfarin therapy for 3 months and above.

Key words: Carbamazepine, Metabolic ratio, Plasma concentration, Warfarin, 7-Hydroxy warfarin.