Journal of Young Pharmacists logo
Communication

Biosensor for uric acid determination based on the combination of polypyrrole and poly (allylamine) films

1★, 1, 1, 1★ Corresponding author

  1. 1Faculty of Pharmacy, Universitas Padjadjaran, INDONESIA.
  2. 2Department of Chemistry, Faculty of Mathematics and Natural Sciences, Jl Raya Bandung Sumedang KM 21, 5 Jatinangor, Jawa Barat, INDONESIA.

CORRESPONDENCE

Aliya Nur Hasanah

Faculty of Pharmacy, Universitas Padjadjaran, INDONESIA.

aliya_nh@yahoo.com

Volume 6, Issue 1 · pp. 39-41 · 2014 · DOI: 10.5530/jyp.2014.1.7

ABSTRACT

Aim and Background: The use of polypyrrole and poly(allylamine) as a matrix of biosensor has been done separately, but the combination of this two has never existed. The purpose of this research is to produce a selective biosensor using combination of polypyrrole (PPy) and poly(allylamine) (PAA) as a polymer for the immobilization of the uricase enzyme, which is used to detect uric acid level in the blood.Materials and Methods: Biosensor manufacturing process began with the electropolimerization of pyrrole on platinum wire then immobilization r turicase enzyme (UOx) with glutaraldehyde as cross-linker, After that, UOx and PAA were deposited via layer-by-layer sequential deposition up to 10 UOx layers to prepare amperometric sensors for uric acid. Biosensor proved to have a linear relationship between the current response and the increase of analyte concentrations, with a correlation coeffi cient (r) = 0.992. Results and Conclusion: Presence of interferences had a little effect on uric acid analysis i.e. 1.39% glucose and1.65% ascorbic acid. The sensors could be used up to 32 times. In the stability test, 13.4% of the initial amperometric response decreased at day 33rd. The results showed that combination of PPy and PAA can be used as a matrix for uric acid biosensor.

KEYWORDS

Open in new tab

REFERENCES

As published

Showing references and in-text citations exactly as published.

    Cite this article

    SELECT FORMAT

    Hasanah, A. N., Wathoni, N., Refiani, A. I., & Wahyuni, Y. (2014). Biosensor for uric acid determination based on the combination of polypyrrole and poly (allylamine) films. Journal of Young Pharmacists, 6(1), 39-41. https://doi.org/10.5530/jyp.2014.1.7

    Copyright and licence

    © 2014 Author(s)

    This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. CC BY-NC-SA 4.0