Journal of Young Pharmacists logo
Article

Quantification of Palbociclib in Spiked Human Plasma Using Liquid Chromatography- Electro Spray Ionization-tandem Mass Spectrophotometry- an Application to Pharmacokinetic Study

1, 1★, 2★ Corresponding author

  1. 1Department of Pharmaceutical chemistry, GITAM Institute of Pharmacy, GITAM (Deemed to be University), Gandhi Nagar, Rushikonda, Visakhapatnam, Andhra Pradesh, INDIA.
  2. 2Vaageswari Institute of Pharmaceutical Sciences, Karimnagar, Telangana, INDIA.

CORRESPONDENCE

Sumanta Mondal

Department of Pharmaceutical chemistry, GITAM Institute of Pharmacy, GITAM (Deemed to be University), Gandhi Nagar, Rushikonda, Visakhapatnam, Andhra Pradesh, INDIA.

mondalresearch@gmail.com

Received: 30-09-2021; Revised: 23-10-2021; Accepted: 03-12-2021.

Volume 14, Issue 1 · pp. 82-88 · 2022 · DOI: 10.5530/jyp.2022.14.16

ABSTRACT

Objectives: The present method was developed for the estimation of palbociclib in spiked human plasma using Liquid chromatographic mass spectroscopy.Methods: The liquid-liquid extraction method was adopted and chromatographic separation was performed on a waters symmetry shield, C18 (4.6mm id x 50 mm) analytical column using (methanol: ultrapure water, pH 4.2 in the volume ratio of 60:40) as mobile phase. Positive ion mode was selected to obtain the product m/z +447.5 (parent) → 380.3 (product) for palbociclib and m/z +434.5 (parent) → 322.7 (product) for internal standard.Results: Calibration curve was linear over the range of 3-600 ng/ml. The intra and interday accuracy with % nominal 95 → 98.4 %, precision %CV ≤ 2% in all quality control levels, The percentage extraction recovery (96.15 % → 98.34 %), demonstrated excellent matrix and analyte selectivity (% interference = 0), and satisfactory stability study results in all types (% nominal 93.91 % → 99.58 %). The pharmacokinetic parameters was studied in the rabbit model, and the area under the curve (AUC0-∞) for palbociclib was 2632 ± 6.98 hr.ng/ml. The elimination half-life (t1/2) is 11.3 ± 5.3 hr.Conclusion: Based on the experimental findings the current developed method was considered a novel validated bioanalytical method, and applied in rabbit blood samples for pharmacokinetic studies of marketed formulations.

KEYWORDS

Open in new tab

REFERENCES

As published

Showing references and in-text citations exactly as published.

    Cite this article

    SELECT FORMAT

    Ramakrishna, B., Mondal, S., & Mondal, P. (2022). Quantification of Palbociclib in Spiked Human Plasma Using Liquid Chromatography- Electro Spray Ionization-tandem Mass Spectrophotometry- an Application to Pharmacokinetic Study. Journal of Young Pharmacists, 14(1), 82-88. https://doi.org/10.5530/jyp.2022.14.16

    Copyright and licence

    © 2022 Author(s)

    This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. CC BY-NC-SA 4.0